Lifter unit with pillar guidance
Lifter unit with pillar guidance
Filling pressure regulation and a composite arrangement are possible
using the cylinder tube base.
To attach the strip guide on the lifter rail, use the provided threads.
We recommend designing the strip guide for a maximum material width
of +0.4 mm (0.2 mm for each side) (View X).
When several lifter units are used, only one unit per piece should be
pinned in order to prevent redundancy.
Note:
The lifter unit is equipped with gas spring type 2482.74.00090, which
cannot be repaired in case of wear and must therefore be exchanged
completely.
Initial spring force: 90 daN
Pressure medium: Nitrogen N2
Max. filling pressure: 180 bar
Min. filling pressure: 25 bar
Working temperature: 0°C to +80°C
Temperature related force increase: +0.3%/°C
Max. recommended extensions per minute: 80 to 100 (at 20°C)
Max. piston speed: see table
Max. usable stroke: 95%