Add to favorites

#Product Trends

IPX12 Ingress Protection Introduction

IPX12 Ingress Protection Introduction

IPX12 Ingress Protection Introduction

IP ingress protection refer to below test standard:

IEC60529,DIN40050-9,ISO20653,IS016750,GB4208,GB/T10485-2007

1.Range;

IP ingress test with number from 1 to 8 means water ingress code from IPX1 to IPX8.

2.Water ingress test method:

(1).IPX1

Test method: Vertical drop test

Test equipment:Drop test devices and test method

Specimens placed:Put the test specimens at 1r/min rotation table as normal working position, keep the distance between the top of the sample and drop nozzle no more than 200mm.

Test condition: drop water volume 1.0+0.5mm/min

Test time: Last for 10 min

(2)IPX2

Test method : 15°to vertical drop test

Test equipment:Drop test devices and test method

Specimens placed: Put test specimens left 15°to vertical

keep the distance between the top of the sample and drop nozzle no more than 200mm.4 faces of sample uniform exposure.

Test condition: drop water volume 3.0+0.5mm/min

Test time:4*2.5mm 10 min

Details

  • Changpingzhen, Dongguan, Guangdong, China, 523790
  • Joy

    Products associated