#Product Trends
IPX12 Ingress Protection Introduction
IPX12 Ingress Protection Introduction
IPX12 Ingress Protection Introduction
IP ingress protection refer to below test standard:
IEC60529,DIN40050-9,ISO20653,IS016750,GB4208,GB/T10485-2007
1.Range;
IP ingress test with number from 1 to 8 means water ingress code from IPX1 to IPX8.
2.Water ingress test method:
(1).IPX1
Test method: Vertical drop test
Test equipment:Drop test devices and test method
Specimens placed:Put the test specimens at 1r/min rotation table as normal working position, keep the distance between the top of the sample and drop nozzle no more than 200mm.
Test condition: drop water volume 1.0+0.5mm/min
Test time: Last for 10 min
(2)IPX2
Test method : 15°to vertical drop test
Test equipment:Drop test devices and test method
Specimens placed: Put test specimens left 15°to vertical
keep the distance between the top of the sample and drop nozzle no more than 200mm.4 faces of sample uniform exposure.
Test condition: drop water volume 3.0+0.5mm/min
Test time:4*2.5mm 10 min