FAQ about INVT Goodrive100-PV Series Solar Pump Inverter
Do you want to know something about INVT Goodrive 100-PV inverter?
Goodrive100-PV Series Solar Pump Inverter
Q1: Keypad display AL-S, and system stop running?
A: AL-S is weak light alarm, means the current sunshine is not enough to drive the pump, result in the running frequency Hz is less than lower limit: (lower limit: P15.05*P00.03)
Conditions of AL-S:
a. Running frequency is less than P15.05*P00.35, and keep more than P15.20 time.
b. Current PV output voltage(P18.01) is less than undervoltage point. (P15.37)
If current condition meets a or b, keypad will display AL-S alarm.
If P15.32=0, the system will switch to AC power input channel.
Q2:Single phase pump cannot start?
A. If the model is -SS2? Only this model supports driving single phase pump.
B. There are 2 ways for single phase pump:
1. Connect pump L&N to inverter U&W.
2. If the first way cannot start, Please remove the capacitors as the following photo, and make sure the resistor value U&V is the biggest OHM, U&W is the smallest value.
Note: after remove the capacitor, must connect S4 & COM terminals on control board.