ProCeas® gas analyser tracking contaminants in ROG treatment unit

gas analyser for trace gas analysis in hydrocarbons (NH3, H2S, H2O, etc.)

AP2E has successfully installed and commissioned a trace analyser to control contaminants (NH3) in a hydrocarbon gas stream enabling the client to recycle the refinery off-gas (ROG) into a low-cost and clean raw material to feed some close petrochemical plants.

Before working with AP2E, the client, one of the main refinery in Belgium, tried several technologies such as UV, without success, due to cross interferences, and detection limits much above the ppb range. The client contacted AP2E to validate the capacity of the ProCeas® to track NH3 in ppb range in heavy hydrocarbons streams. Tests were conducted successfully in AP2E workshops, and a ProCeas® NH3 was installed on the process, with a pressurized ATEX wall-mounted enclosure.

Once again, the unique laser technology OFCEAS and Low Pressure Sampling (LPS) proved to be on the top of the analytical solutions to track contaminants in refinery ROG treatment units.