Add to favorites

#Product Trends

Packing Machine AF-25K Installation and Operation Guide

You can use General Measure's packing scale to pack different granule materials, but how to set the formula parameters? Let's check it out in the video.

1.Installation of AF-25K Packing Scale

Step 1: Open the side door with the triangular key

Step 2: Remove the four fixing screws of the measuring hopper and take them off

Step 3: Take out the measuring hopper from the door on the side with air cylinder, and then remove the four lugs on the hopper.

Step 4: The air pipe installed should be placed on the same side of the electric control box.

Step 5: Lift the measuring hopper parallel to the dovetail groove into the scale, and then install the four lugs.

Step 6: Connect the air pipe according to the color classification.

Installation complete.

2.Calibration of AF-25K Packing Scale

Step 1: Administrator logged in

Step 2: Enter the “Calibration” interface

Step 3: Click on “Zero Calibration” when the hopper is empty and the weight is stable.

Step 4: Hang a 5kg weight on the hopper.

Step 5: Input 5kg, wait until the weight is stable, and then click “Calibrate Weights”.

Calibration complete.

3.Formula Setting of AF-25K Packing Scale

Step 1: Set the target value first

Step 2: Set up the fast fill advance data, fast fill opening degree, drop value, slow fill advance data, slow fill opening degree, and drop value.

Step 3: Click the “Start” to get some packing results

Step 4: According to the packing result, adjust and optimize the formula parameters reasonably.

Here is the reference table for packing parameters setting for AF-25K. The figures on the table are just for reference only. In regards to different structure and materials of the packing scale, please consult technical support for specific setting.

Packing Machine AF-25K Installation and Operation Guide

Details

  • Shenzhen, Guangdong Province, China
  • Shenzhen General Measure Technology

    Keywords