Add to favorites

#Product Trends

Hot line proximity alarm

HXW-6W

■Specification
Working voltage range:1kV to 42kV
Alarm starting distance:60cm against 6.6kV(3.8kV to ground)
Frequency:Both 50Hz and 60Hz
Sound volume:65dB or more(60cm apart)

■Operation Voltage Distance Table(Theoretiacal value)
Normal voltage Operation Distance
6.6kV 0.6m
11kV 0.8m
22kV 1.1m
33kV 1.3m

FLYER

Details

  • 661-0976, Japan
  • AYAKA MAEDA