video corpo
Add to favorites

#Product Trends

Proximate analyzer / Thermogravimetric / TGA / Coal / Coke / Biomass SDTGA5000a | ASTM D 7582 | 16 Autoloader | 60~90min

Sundy proximate analyzer SDTGA5000a is the proximate tester which can be used to determine the moisture, ash and volatile matter as well as calculation of fixed carbon for coal, coal and biomass. Testing result is accurate and reliable.

Application

Proximate analyzer can be used to determine the moisture, ash and volatile matter as well as calculation of fixed carbon for coal, coal and biomass.

Conformance to Standards

ASTM D 5142-09 - Standard Test Method for Proximate Analysis of the Analysis Sample of Coal and Coke by Instrumental Procedures.

ASTM D7582 - Standard Test Methods for Proximate Analysis of Coal and Coke by Macro Thermogravimetric Analysis

ASTM D 3173-03 Standard Test Method for Moisture in the Analysis Sample of Coal and Coke

ASTM D 3174-04 - Standard Test Method for Ash in the Analysis Sample of Coal and Coke.

ASTM D 3175-07 Standard Test Method for Volatile Matter in the Analysis Sample of Coal and Coke.

ISO 11722 - Solid Mineral Fuels - Hard Coal - Determination of Moisture in the General Analysis Test Sample by Drying in Nitrogen.

ISO 1171 - Solid mineral fuels - Determination of Ash.

ISO 562 - Hard coal and coke - Determination of Volatile Matter.

Specification

Moisture: 1~16 samples

Ash: 1~16 samples

Volatile Matter: 1~10 samples, 7min

Self-defined Method: Available

Sample Mass: 0.5 ~ 1.1g

Temperature Control Precision: ±2℃ (moisture) , ±5℃(ash, volatile matter)

Furnace Temperature Range: Room temperature to 1000 ℃

Analytical Balance Precision: 0.0001g

Air Flow: 5L/min ~ 12L/min

Power Requirement: 220 V(-15%~10%),50/60 Hz

Max. Power: 4kW

Highlights

1.Simulate test environment and condition of drying oven and muffle furnace. Applicable for all type of coal analysis.

2.Assembly line operation mode. Sample weighing, introducing, test, taking, discarding and data processing can be finished automatically. Fast test speed, high efficiency.

3.Balance away from high temperature and heat radiation. No drift occur. Precise sample mass from beginning to the end of test can be ensured.

4.With special volatile matter crucible and unique automatic sample delivery mechanism, operator do not need to place/take crucible cover under high temperature.

5.Patents ensure the reliability and stability of mechanic movement system. No crucible fall off or turn over.

6.Compressed air can meet the requirement of gas supply, no oxygen and nitrogen required.

7.Capable of connecting with network and balance by RS232 interface.

8.With CAN bus interface, several proximate analyzers can be controlled by a single PC.

Details

  • Hunan, China
  • Sundy Science and Technology