Add to favorites

#Product Trends

LDW-80T Impact Test Low Temperature Chamber

Low Temperature Chamber

Application of Equipment

LDW-80T Impact Test Low Temperature Chamber is the compressor refrigeration equipment newly developed by our company according to the requirements for low temperature devices in JB-5376-1991 Technical requirements of low temperature constant temperature tank and GB/T 8363-2018 Steel-Drop-weight tear tests method. This equipment adopts cascade type compressor refrigeration technology, heat balance principle and circulating stirring method to achieve automatic cooling uniformly and constant temperature of the test specimens, which can fully meet the various temperature control indicators stipulated in relevant standards. This equipment adopts single chip microcomputer technology control, digital display temperature value, automatic temperature control, automatic timing, automatic alarm, simple and safe operation, fast cooling speed, large volume, high temperature control accuracy, which is the most ideal equipment for metal material in low temperature impact test sample cooling and heat preservation equipment. It can also be used for other low-temperature detection and test work.

Applicable Standards

1.JB-5376-1991Technical requirements of low temperature constant temperature tank

2.GB/T 8363-2018 Steel-Drop-weight tear tests method

3.ASTM E436-2003 Standard Test Method for Drop-Weight Test Tests of Ferritic Steels

4.GB/T 6803-2008 Test method for drop-weight test to determine nil ductility transition temperature of ferritic steels

5.ASTM E208-2017 Standard Test Method for Conducting Drop-Weight Test to Determine Nil-Ductility Transition Temperature of Ferritic Steels

Main Technical Parameters

Technical Parameters

Temperature control range +30~-80℃

Temperature control accuracy ≤±0.5℃

Temperature uniformity ≤2℃

Cooling speed (when room temperature is 25℃) Room temperature~0℃ About1.3℃/min

0℃~-40℃ About1.1℃/min

-40℃~-60℃ About1.0℃/min

-60℃~-80℃ About 0.8℃/min

Heating speed About 2℃/min

Size of cooling tank About 60L

Digital timer 1minute ~ 9999 minutes, resolution:1minute

Effective size of cooling tank 570×390×230mm (length x width x height)

Specimen basket 2 pieces

Number of specimen can be placed 22 pieces (Falling impact specimen size : 305×76.2mm, thickness is according to original material; Specified specimen size in national standard, : 305±5×76.2±1.5mm)

Digital timer 1minute ~ 9999 minutes, resolution:1minute

Cooling medium Absolute ethyl alcohol

Dimension 1510×1010×1160mm

(length x width x height, not including the protuberant part)

Power supply Three phases five wires, 380V, 50HZ

Power 14kW

Operating environment temperature 5℃~30℃

Details

  • Shandong, China
  • Jinan Liangong Testing Technology Co., Ltd