Add to favorites

#Product Trends

Food and Pharmaceutical industries RTD temperature probes 1601

Applications:

Food and Pharmacy industries etc.

Technical data

Protection tube:stainless steel 304/316

Terminal head: stainless steel 316

Sensor element: Pt100 meets IEC 751

Tolerance : Class A: △t=±(0.15 + 0.002 |t| )℃(standard)

1/3Class B: △t=±(0.10 + 0.0017 |t| )℃

Protection Class: IP65

Transmitter:Output 4-20mA, 2-wire Power supply: 12-30VDC

Load resistance 0-600Ω/24V

Accuracy:±0.5%FS,±0.2%FS(optional)

Order Details:

TM1601 —(1)—(2)—(3)—(4)—(5)— (6)/(7)

(1)protection tube diameter D

6 6mm

8 8mm

9 9mm

11 11mm

(2)Insertion length EL

50 50mm

100 100mm

150 150mm

200 200mm

250 250mm

Note: other lengths as per customers’ requirements(EL≤1000mm)

(3)Process connection G

213 G1/2 thread

410 DN10 DIN11851

411 DN25 DIN11852

412 DN32 DIN11853

413 DN10/20 DIN32676

414 DN25/40 DIN32677

415 DN50 DIN32678

416 DN10/15 VARIENT

417 DN25/32 VARIENT

418 DN40/50 VARIENT

510 Spherical welding units

Details in “Thread code table”

(4)Sensor element

11 1 x Pt100 in 2-wire circuit

51 1 x Pt500 in 2-wire circuit

61 1 x Pt1000 in 2-wire circuit

13 1 x Pt100 in 3-wire circuit

14 1 x Pt100 in 4-wire circuit

12 2 x Pt100 in 4-wire circuit

16 2 x Pt100 in 6-wire circuit

62 2 x Pt1000 in 4-wire circuit

(5)Measuring range

14 -50℃ ~+ 260℃

(6) Cable length L(L≥100mm)

100 100mm

200 200mm

2000 2000mm

Note: other lengths as per customers’ requirements

(100mm≤L<1000mm, L1=50mm, L≥1000mm, L1=100mm)

(7)Additional options

00 No

02 shielded connecting cable

06 Output 4-20mA in 2-wire

07 Ferrules as per DIN 46 228 part 4(standard)

08 Multipole connector (providing types)

99 Special options

List the additional options in sequence, separated by commas.

Details

  • Dalian Bocon Science & Technology Co. Ltd

    Keywords