PGC

With its way of operation and the saved measurement report, all documentation can be reproduced quickly and completely. You can save measurements in the PGC and print them out again later. To use the devices, no carrier gas and no second measuring device are required.

Energy is provided by the internal battery, with the device also able to run using the 230 V charger or from the 12 V motor vehicle power supply.

Delivered as a complete set.

Natural gas always contains ethane; the presence of this gas is also evidence of natural gas.

Normally a drawn-out gas analysis is required to assure that the measured gas concentration really is natural gas and not marsh gas. This time-consuming and difficult work, as well as the sampling, is no longer needed at all. Simply measure and save directly at the bore hole.

The printout can be done after the measurement.

No other measuring instrument are required. This gas chromatograph complies with the requirements of the DVGW (G465-4).

With the new and unique PGC you can quickly distinguish between marsh gas, natural gas and propane. Thanks to the integrated measurement cell of the PGC, no additional measurement instrument is required to analyse the gas, nor do you need any expensive carrier gas.

simple

light

strong

ethane can be attested at the bore hole

no laboratory analysis

complying with DVGW regulations

written documentation

standard battery

determines hydrogen, methane, ethane und propane

saved measurements

universal power supply, 12V, 230V, battery

automatic supply commutation

delivered as a complete set

Measurement sequence

Turn instrument on

Connect gas sample

Start measuring

Gather measurement record

It is this easy to obtain, in just a few minutes, the evidence of ethane – and combined with the thermal printer even in black and white. By means of the measurement record you can clearly determine and sustainably document if it is natural gas, marsh gas or propane. The PGC may be connected to 230V alternating voltage, to the car voltage, or it may be used without external power supply by means of the integrated batteries. Also the thermal printer can be used anywhere thanks to the integrated accumulator.

The measurements can be saved and printed again later on.

Portable Gas Chromatograph PGC

Carrying case watgerproof

Gas sample bag

Adapter model 20 and model 21

Printer

12V power source

230V power source

Certificate

Manual