Add to favorites

#Industry News

FUNCTIONAL SAFETY CERTIFIED LOAD LIMITER ELECTRONICS

Performance level “PL d” according to EN ISO 13849-1 / “SIL 3 rady”

Overload protection electronics for hoisting devices with certification for performance level PL d according to EN ISO 13849-1.

o 2 redundant channels with constant comparing of both signals

o PFHd 4.29 x 10E-08

o Load limiter electronics certified for functional safety up to PL d Category 3, DC: medium

o Display of hoisted load and input signal

o Monitoring system of the integrity of load cells with continuous comparison of both channels and internal "watchdog" for the electronics

o Analogue output: 2 x 4...20 mA

Details