Clamp-On Flow Meter now available for Ex-Applications

The flow metering of liquids can be realized in prssurized pipelines with deltawaveC without cutting the pipe. The ultrasonic transducer can be mounted just within minutes under operating pipes between 10 and 6000mm. Both - transducers and the converter electronics - are now available for Zone I and Zone II. This allows the safe use in hazardous areas eg in chemistry or in refineries.

The clamp-on transducers withstand fluid temperatures from -40 to 160 ° C. The precise ultrasonic transit time method ensures an accuracy of 1% in the wide measuring range.