Add to favorites

#Product Trends

TBB Power NEW inverter charger

TBB Power Co., Ltd launched its new generation inverter/charger combination with following new features:

CCT controller, optional device

Power Save Mode

Weak grid

Solar mode

Gen mode

Manual Equalization

Model No. CT0825L CT1240L CT1645L

CT0815M CT1220M CT1625M

Gen mode yes yes yes

Weak grid mode yes yes yes

Solar mode yes yes yes

INVERTER

Nominal Voltage 12Vdc/24Vdc

Cont. power @25℃(VA)【1】 800 1200 1600

Cont. power @25℃(W) 750 1100 1400

Cont. power @40℃(W) 700 1000 1250

Output voltage 230AC ± 2%

Output frequency 50/60Hz ± 0.1%

Cosφ 0.9-1

Overload Capability 【2】 >110% 15mins

>125% 60s

>150% 20s

Surge 300%

Efficiency (MAX.) 12V 0.89

24V 0.92

THD 【3】 <3%

Zero load power 9W 10W 13W

Zero load power (power save mode) 2.3W 2.5W 3.5W

Overload and overheat protection auto disconnect with 3 times restart attempt

shortcut protection auto disconnect

Charger

Nominal Output Voltage 12Vdc/24Vdc

Max Output current (A) - adjustable 25/15 40/20 45/25

AC Input range (UPS mode) 190VAC - 264VAC, 45-65Hz

Battery types AGM / GEL / Semi Traction / Traction

Absorption time variable

Temperature compensation -4mV/℃/cell

Slave Charger 3-5A float charge

Other Data

Transfer time UPS mode 15ms

GEN mode 2s

Transfer switch 16A

Dry contact Battery low

Battery connector M6 x 2

AC terminal M3

Enclosure Steel with powder paint

Dimension (mm) (max) 440×232.5×110

Net Weight (KGs) 10.7 11.8 12.3

Cooling Forced fan

Protection IP20

Standard

Safety EN60950-1

Emission EN55022

Immunity EN55022

Details

  • TBB POWER Co., Ltd

    Keywords