video corpo cad

ATEX motors "DELPHI EX"

Giorgio Bosio
Add to favorites

designed and certified, like Motive "EX" gearboxes, for ATEX categories 2 and 3, Gas and Dust, zones 1, 21, 2, 22

also motive three phase motors of the DELPHI series, like motive gearboxes before (BOX worm, ENDURO helical bevel, STON mounted shaft helical, ROBUS in-line helical, STADIO pre-stage) have just been certified ATEX for category 2 and 3.

DELPHI EX are then suitable now for 4 zones, 2 categories, Gas and Dust

Cat Zone description motive gearboxes

2 1 A place in which an explosive atmosphere consisting of a mixture with air or flammable substances in the form of gas, vapor or mist is likely to occur in normal operation occasionally

3 2 A place in which an explosive atmosphere consisting of a mixture with air of flammable substances in the form of gas, vapor or mist is not likely to occur in normal operation but, if it does occur, will persist for a short period only.

2 21 A place in which an explosive atmosphere in the form of a cloud of combustible dust in air is likely to occur in normal operation occasionally.

3 22 A place in which an explosive atmosphere in the form of a cloud of combustible dust in air is not likely to occur in normal operation but, if it does occur, will persist for a short period only.

aluminum and cast-iron ATEX motors
aluminum and cast-iron ATEX motors

TEX is the conventional name of the Directive 94/9/EC for the equipment intended for use in potentially explosive atmospheres. Motive DELPHI Ex motors differ from standard DELPHI motors because they are designed to be used, like motive "Ex" gearboxes, in the ATEX zones 1, 2, 21 and 22, all Groups A, B and C, categories 2 and 3 Cat 2 zone 1 GAS A place in which an explosive atmosphere consisting of a mixture with air or flammable substances in the form of gas, vapor or mist is likely to occur in normal operation occasionally. yes Cat 3 zone 2 GAS A place in which an explosive atmosphere consisting of a mixture with air of flammable substances in the form of gas, vapor or mist is not likely to occur in normal operation but, if it does occur, will persist for a short period only yes Cat 2 zone 21 DUST A place in which an explosive atmosphere in the form of a cloud of combustible dust in air is likely to occur in normal operation occasionally. yes Cat 3 zone 22 DUST A place in which an explosive atmosphere in the form of a cloud of combustible dust in air is not likely to occur in normal operation but, if it does occur, will persist for a short period only. yes Motive DELPHI EX motors are in fact certified for such zones according to the norms EN 60079-0 - EN 60079-7 - EN 60079-31 by a notified body II 2G Ex eb IIC T4 Gb II 2D Ex tb IIIC T135°C IP65 Db Tamb=-20 +40 °C

ATEX certificate

Associated Trend items