#Industry News
Temperature Forcing System for Cold-Start IC Offset Testing
Learn when to measure IC output offset at cold startup and steady state, which limit applies, and how the SANWOOD Temperature Forcing System controls the test site.
Which reading determines whether the IC passes at cold startup?
In semiconductor reliability testing, an automotive sensor interface IC may exceed its output offset limit just after the output is required to be valid, then recover before the package reaches a stable operating temperature. If acquisition starts after stabilization, the report can document the steady-state result and should mark cold startup as unmeasured.
For an analog output, use the input condition specified for the offset test, such as zero differential input. Compare the measured output voltage with the specified nominal output, keeping the supply, reference voltage, and output load consistent with the test definition. Check whether the limit applies to the offset at the cold test point or to the change from a room-temperature baseline. If the limit applies to the change, retain the room-temperature reading for each device.
Set the startup and steady-state measurement windows
For the cold-start check, bring the unpowered IC to the specified starting temperature. Capture the output around the trigger defined in the device specification. A supply crossing its operating threshold and an enable signal going high can occur at different times. Mark the trigger and the start of the output-valid window on the same trace. Apply the offset limit from the specified instant, along with any duration rule for that window.
For the steady-state check, keep the device operating under the specified load. Take the offset reading once the powered package has stayed within the required temperature tolerance for the specified interval. If the output exceeds its applicable limit during startup and later recovers, record both results against their respective criteria.
Where the SANWOOD Temperature Forcing System fits
The SANWOOD Temperature Forcing System directs temperature-controlled air through a thermal head to the IC package. Air Mode controls the delivered air temperature, while DUT Mode uses temperature feedback from the device under test. The system accepts external Type T and Type K thermocouples. A separate power supply powers the board, and external instruments capture the IC output.
The package can warm after power-on as the IC dissipates heat, even with a constant air setpoint. If the test specifies package-surface temperature, mark the thermocouple attachment point on the fixture drawing and record the temperature through startup and into steady state. Check the setup with the electrical probes installed so the thermal head can sit in its intended position. If the entire board and its reference circuitry need to share a specified ambient condition, consider an environmental test chamber for the powered fixture.
Discuss your test setup with SANWOOD
Send SANWOOD the IC package dimensions, target temperature and tolerance, expected power dissipation, and a fixture drawing showing the thermocouple and electrical probe locations. Include the startup trigger and the earliest time the output must be valid. These details help SANWOOD review thermal head placement and probe access for your application.
Explore more semiconductor testing articles on SANWOOD’s website: https://www.sanwood.us/news/222.html
View the SANWOOD Temperature Forcing System: https://www.sanwood.us/products/187.html
Contact SANWOOD at [email protected].
鄂公网安备42018502009509号