TELE now with railway certification

Our TELE VEOs now also with railway certification according to EN 50155:2008

Our types:

• V2ZA10 3Min 24-240V / V2ZA10 10Min 24-240V

• V2ZI10 12-240V AC/DC / V2ZI10P 12-240V AC/DC

• V2ZM10 12-240 V AC/DC / V2ZM10P 12-240V AC/DC

• V2ZS20 12-240V AC/DC / V2ZS20P 12-240V AC/DC

Application 1

The wagons are supplied from batteries and inverters when the train travels over a currentless section. If currentless travel takes too long, consumers are switched off one by one. A release-delayed time relay is utilized for this purpose. When the voltage is disconnected, the timer begins and the consumer is switched off according to the set time. If the voltage returns before the set time expires, the consumer remains switched on.

Application 2

When starting up the diner car, cooling units are switched on with a time delay; this is necessary because the superordinated control requires a certain amount of time to start up. A release-delayed time relay is utilized for this purpose.