Brazing Aluminum to Aluminum
The objective of the application test is brazing Aluminum to Aluminum in less than 15 seconds. We have aluminum tubing and an aluminum “receiver”. The brazing alloy is an alloy ring, and has a flow temperature of 1030F.
Equipment
Ultraheat UPT-S5 Power Supply
HS-4 Heat Station
Induction Coil
Materials
• Aluminum tube: 0.167” OD, 0108” ID
• Aluminum component: ID .1675”, depth .288”,
chamfer at top area is 0.2375” ID max
• Braze alloy in the form of two-turn alloy ring
• Flux
Key Parameters
Temperature: 1030F
Power: 2 kW
Time: 14 seconds
Frequency
107 kHz
Process:
The Aluminum component and tube were assembled together with the alloy ring. Flux was added.
The part was positioned in the induction coil.
Several tests were conducted with different cycle times to confirm the heating time for a good braze.
At 15 seconds the assembly melted.
At 14 seconds, we had success for brazing aluminum to aluminum, and a good quality braze joint was achieved.
Results/Benefits:
The 5 kW system requested by the customer, will meet the customer’s time requirements for brazing.
Precise control of the time and temperature
Power on demand with rapid heat cycles
Repeatable process, not operator dependent
Safe heating with no open flames
Energy efficient heating