Installation of Infrared Radiation Thermometer for combustion gas temperature simplified with Focused High Precision Optics

The use of Infrared Radiation Thermometers for combustion gas temperature requires a channel or view port with diameter larger than the field of view of the Infrared Radiation Thermometer. When installed on incinerators, the cooling tubes in the fin wall would typically be bent to create the opening.

• The requirement to bend the tubes can be avoided by creating a ≥ 10 mm hole between two tubes.

• Infrared Radiation Thermometers

→ measure combustion gas temperature fast and reliable

→ do not age like thermocouples do