#Product Trends
How to Choose a Thermal Camera for Solar Panel Inspection
Test your current camera from an accessible spot. If it shows the module and the warm patch clearly, you already have the right camera; if not, move closer before choosing a lens.
Site Surveys and Ground Inspection
When surveying a solar installation, cover the array consistently and record the location of any suspicious modules. An aerial survey can cover a large array quickly. For smaller installations, a handheld thermal camera may be sufficient if every module is accessible and visible from the ground.
During a follow-up inspection, use the row and module ID to locate the flagged module. First, take a visible-light photograph that includes enough of the surrounding row to help another technician identify the correct location. Then use the thermal camera to focus on the module and show where the warm area appears.
Raythink's photovoltaic applications guide explains how technicians use surface temperature patterns to inspect photovoltaic modules and identify potential thermal abnormalities.
Evaluating Your Thermal Camera
If your primary objective is to identify a suspicious module, the image should include enough of the surrounding row to help another technician locate it. However, if you need to show a warm patch within an individual solar cell, you should estimate the actual width of the patch itself. Using the entire cell width will overestimate the number of pixels covering the thermal anomaly.
Start by measuring the distance between the camera lens and the module from your intended inspection position. At this distance, the lens's field of view (FOV) determines how much of the solar array can fit into the image. Its instantaneous field of view (IFOV) represents the angle covered by a single thermal detector pixel. A smaller IFOV means more pixels can cover the same thermal feature at an identical working distance.
Although digital zoom can enlarge an image, it does not provide additional optical detail. For a better understanding of the differences between digital and optical zoom, see our guide to choosing an industrial handheld thermal camera.
Take a thermal image using your current camera from the position you intend to use during inspection. Check whether the warm patch is clearly visible on the cell and whether its boundaries can be distinguished. If the feature is difficult to identify, try moving closer or adjusting the viewing angle to obtain a more direct view of the module.
If you have a clear view but cannot move closer, compare different lens options based on the number of pixels they can place across the thermal feature at that distance. Use these estimates to narrow down your lens choices, then evaluate actual images to determine whether the available detail meets your inspection requirements.
If your inspection requires reporting temperature differences, you should also check the minimum measurement area that the camera and lens can accurately measure at your working distance. The warm patch must adequately cover this area, commonly referred to as the measurement spot. Make sure that emissivity and reflected apparent temperature are configured according to your inspection procedure.
Standard vs. Telephoto Lenses
A standard lens provides a wider field of view, allowing you to capture the suspicious module together with its neighboring modules in one image. It is suitable when you can get sufficiently close to distinguish the required thermal details while keeping enough of the surrounding array visible.
A telephoto lens is worth considering when the module is clearly visible but your inspection position does not allow you to move closer. Its smaller IFOV places more pixels across the warm area, making it easier to distinguish smaller thermal features at greater distances. However, its narrower field of view may exclude module edges or row identification markers.
If both an overview image and a detailed thermal image are required, make sure that both images carry the same module ID. This allows technicians to connect the detailed thermal anomaly with its exact location in the solar array.
Inspection conditions also matter. If you notice glare, can only view the glass at a shallow angle, or encounter physical obstructions, try another accessible inspection position. Check the visible-light image for dirt or shading and compare modules under similar sunlight and operating conditions.
Reflections can sometimes appear as thermal abnormalities. If an apparent hot spot moves across the glass as you change your viewing angle, it may be caused by reflected radiation rather than an actual temperature anomaly. A University of Cádiz study conducted at a 100 kW photovoltaic plant demonstrated how ground-based inspections can help researchers recognize the effects of shading and solar reflections.
If the module remains inaccessible from the ground, arrange an alternative viewing position or an additional aerial inspection. If the thermal patch remains in the same location, document it for further investigation. However, additional evidence is necessary before identifying the specific electrical cause of the abnormality.
Raythink | Raytron Industrial Thermal Cameras for Solar Inspection
If you have a clear view of the module from the ground, compare the standard lens configurations at your actual working distance. Consider whether each configuration can clearly show the warm patch while retaining enough of the module in the frame to identify its location.
If the standard lenses cannot provide sufficient detail and moving closer is not possible, consider the telephoto lens options available for the RT400 and RT630.
Standard Lens Options
The RM620, RT400, and RT630 offer different combinations of thermal resolution, focal length, field of view, and instantaneous field of view to accommodate different inspection requirements.
The RM620 features a native thermal resolution of 640 × 512 and a 19 mm standard lens, providing an FOV of 23° × 18° and an IFOV of 0.63 mrad. Its manual focusing capability and relatively narrower field of view make it suitable for inspections where the required module area fits within the frame and manual focus adjustment is acceptable.
The RT400 features a native thermal resolution of 480 × 360 and a 17.7 mm standard lens, delivering an FOV of 25° × 20° and an IFOV of 0.92 mrad. It provides multiple focusing options, including autofocus, making it suitable for applications where flexible focusing is important and the standard lens provides sufficient thermal detail for inspection reports.
The RT630 combines a native thermal resolution of 640 × 512 with a 17.7 mm standard lens, offering an FOV of 25° × 20° and an IFOV of 0.68 mrad. Like the RT400, it supports multiple focusing options, including autofocus. However, its higher native thermal resolution provides more detector pixels within the same field of view.
Although the RM620 and RT630 share the same native thermal resolution of 640 × 512, their standard lens configurations differ. From the same inspection position, the RT630 provides a slightly wider field of view, allowing more of the module edges to remain visible alongside the warm patch.
Optional Telephoto Lenses
For inspections requiring greater thermal detail at longer working distances, both the RT400 and RT630 support optional telephoto lens configurations.
The 31.5 mm telephoto lens provides an FOV of 14° × 11.2°. Its IFOV is 0.52 mrad for the RT400 and 0.38 mrad for the RT630. Compared with the standard lens, this configuration places more pixels across the same thermal feature, making it easier to identify smaller warm areas. At the same time, it retains a wider surrounding view than the super telephoto lens, helping technicians maintain some visibility of the surrounding module area.
The 60.9 mm super telephoto lens offers a narrower FOV of 7° × 5.6°, with an IFOV of 0.27 mrad for the RT400 and 0.20 mrad for the RT630. Among the available lens options, it provides the greatest pixel coverage across the thermal feature at the same working distance. This makes it particularly useful when inspecting small thermal anomalies from relatively long distances. However, its narrower field of view may crop out the edges of the solar module, so technicians should consider whether additional overview images are necessary.
Practical Example: Ground Inspection After an Aerial Survey
Consider a hypothetical scenario in which an aerial survey identifies a suspicious solar module that requires a closer ground inspection.
From the service aisle, the technician can clearly see the module but cannot move closer because of site restrictions. The inspection objective is to identify the location of a warm patch within an individual solar cell.
Assume the following inspection conditions:
Working distance: 12 m
Viewing angle: Nearly straight-on
Warm patch width: 36 mm
If the RT630's standard lens allows the technician to identify the module but does not provide enough detail to determine where the warm patch is located within the cell, the 31.5 mm telephoto lens is a reasonable next option.
At the assumed working distance of 12 m, the 31.5 mm lens captures approximately 8 pixels across the 36 mm warm patch, compared with approximately 4 pixels using the standard lens. Meanwhile, the horizontal field width decreases from 5.3 m to 2.9 m.
If greater thermal detail is still required, the technician can consider the 60.9 mm super telephoto lens. This configuration captures approximately 15 pixels across the same warm patch, while reducing the horizontal field width to 1.5 m.
These estimates provide a practical basis for comparing different lens configurations under the same inspection conditions. However, pixel coverage alone does not guarantee that a thermal anomaly will be visible under actual site conditions or determine how accurately its temperature can be measured. The final selection should be based on actual imaging results and the requirements of the inspection report.
Key Buying Considerations
Before purchasing a thermal camera for solar panel inspection, consider the following factors to ensure that the selected configuration meets your actual application requirements.
1. Inspection and Reporting Requirements
Determine what the inspection report needs to demonstrate. Is the objective simply to identify a suspicious module, show a warm patch within an individual cell, or measure a temperature difference? Different requirements may call for different thermal resolutions and lens configurations.
2. Working Distance and Inspection Position
Identify the nearest and farthest accessible inspection distances. Also consider the smallest thermal feature that needs to be captured, together with potential glare, viewing-angle limitations, and physical obstructions.
3. Lens Configuration and Measurement Capability
Confirm which lens is included in the camera package. Check its focusing method, field of view, and IFOV to ensure that it provides sufficient detail at your intended working distance. If accurate temperature readings are required, also verify the minimum measurement spot size for the selected configuration.
4. Available Lens Options
When standard lenses cannot provide sufficient detail, ask about available telephoto configurations. Provide the manufacturer with the dimensions of the smallest feature you need to identify, your expected working distances, and the specific information required in your inspection report.
For professional guidance on selecting the right configuration, contact Raythink | Raytron Industrial. The technical team can help you evaluate whether a standard lens configuration is sufficient or whether an additional telephoto lens is more appropriate for your solar panel inspection application.