IPX56 Ingress Protection Introduction

IPX56 Ingress Protection Introduction

IPX56 Ingress Protection Introduction

IPX5
Test method: Water Spray Test
Test equipment:Spray nozzle diameter is 6.3mm
Test condition:keep the distance between test specimens and spray nozzle 2.5 to 3 m. Water volume12.5L/min(750L/h)
Test time:Calculated by specimens enclosure superficial area , 1min each square meter, at least 3 min.

IPX6
Test method:Strong water spray test
Test equipment:Spray nozzle diameter is 12.5mm
Test condition:keep the distance between test specimens and spray nozzle 2.5 to 3 m. Water volume100L/min(6000L/h)
Test time:Calculated by specimens enclosure superficial area , 1min each square meter, at least 3 min.
D=6.3mm Water ingress level 5 and 6K
D=12.5mm Water ingress level 6